Product Overview
The OxyGo NEXT is a lightweight, portable oxygen concentrator designed for ease of use and travel. Weighing just 4.5 pounds, it delivers up to 5 L/min of oxygen, making it ideal for patients requiring supplemental oxygen. With a built-in battery lasting up to 4 hours, it ensures continuous oxygen supply on the go, catering to the needs of active individuals.
1.1. Key Features of the OxyGo NEXT
- Lightweight and portable, weighing only 4.5 pounds for easy mobility.
- Delivers up to 5 L/min of oxygen flow, suitable for most patient needs.
- Built-in battery provides up to 4 hours of operation without AC power.
- Dual battery option extends runtime up to 13 hours for extended use.
- Rechargeable via AC or DC power, with a recharge time of up to 6 hours.
- High oxygen concentration output ensures reliable supplemental oxygen.
- Includes a carrying backpack for convenient transport.
- Compatible with Bluetooth for enhanced connectivity and monitoring.
- Easy-to-use interface with pulse dose settings (1-6).
1.2. Technical Specifications
- Weight: 4.5 pounds for portability.
- Dimensions: Compact design for easy handling.
- Oxygen flow settings: 1-6 pulse doses.
- Single battery life: Up to 4 hours.
- Double battery life: Up to 13 hours.
- Recharge time: Up to 6 hours with AC/DC power.
- Power consumption: Efficient for extended use.
- Noise level: Quiet operation for patient comfort.
Manuals and Guides
Access comprehensive manuals for OxyGo NEXT, including the User Manual, Getting Started Guide, Column Change Guide, and Bluetooth User Guide, available for free PDF download here.
2.1. User Manual for OxyGo NEXT
The User Manual for OxyGo NEXT provides detailed instructions for operating and maintaining the device. It covers essential topics such as intended use, contraindications, and general precautions. Available in English, Spanish, and French, the manual ensures accessibility for a diverse user base. Users can download the PDF version directly from the official website or authorized distributors. The manual includes step-by-step guides for setting up the device, using the built-in battery, and troubleshooting common issues. It also outlines safety guidelines and maintenance tips to ensure optimal performance. Refer to the manual for comprehensive guidance on using the OxyGo NEXT effectively. Download here.
2.2. Getting Started Guide
The Getting Started Guide for the OxyGo NEXT is designed to help new users quickly understand and begin using the device. This concise guide covers essential steps such as unpacking, assembling, and initializing the oxygen concentrator. It also explains how to properly use the battery, connect AC/DC power, and navigate the device’s controls. The guide emphasizes safety precautions and provides a checklist for ensuring everything is ready for operation. Available as a PDF download, it is an invaluable resource for first-time users. By following the guide, users can ensure a smooth and safe transition to using the OxyGo NEXT. Download the guide for easy reference.
2.3. Column Change Guide
The OxyGo NEXT Column Change Guide provides step-by-step instructions for replacing the sieve columns in your oxygen concentrator. This process is essential for maintaining optimal performance and ensuring continuous oxygen delivery. The guide outlines the tools needed, such as a Phillips screwdriver, and walks users through turning off the device, preparing the columns, and securely reinstalling them. It emphasizes safety precautions to avoid damage or contamination. Available as a downloadable PDF, the guide includes visual aids and troubleshooting tips for common issues during the column replacement process. Regular column maintenance ensures the longevity and effectiveness of your OxyGo NEXT.
2.4. Bluetooth User Guide
The Bluetooth User Guide for the OxyGo NEXT explains how to connect your oxygen concentrator to compatible devices via Bluetooth. This feature allows seamless integration with smartphones or tablets, enabling users to monitor oxygen flow settings, battery life, and device status remotely. The guide provides step-by-step instructions for pairing the device, troubleshooting connectivity issues, and using the OxyGo app to customize settings. It also covers resetting the Bluetooth module and ensuring a stable connection for uninterrupted monitoring. This guide enhances the user experience by offering convenient control and real-time updates, ensuring optimal use of the OxyGo NEXT.
How to Use the OxyGo NEXT
The OxyGo NEXT is simple to operate. Turn it on, adjust the flow setting, and monitor oxygen delivery. Use the Bluetooth app for remote control and updates.
3.1. Setting Up the Device
Setting up the OxyGo NEXT is straightforward. Begin by unpacking and inspecting the device. Connect the power supply and charge the battery fully before first use. Ensure all accessories, like the nasal cannula, are securely attached. Turn on the device and adjust the flow setting as prescribed by your healthcare provider. Use the control panel to select the appropriate pulse dose setting. Refer to the user manual for detailed instructions on initial setup and customization. Always follow safety guidelines to ensure proper operation and oxygen delivery. Proper setup ensures optimal performance and safety for users.
3.2. Operating the Oxygen Concentrator
To operate the OxyGo NEXT, press the power button to turn it on and select the prescribed flow setting using the control panel. Adjust the pulse dose setting according to your healthcare provider’s instructions. Ensure the device is placed on a stable surface with proper ventilation. Monitor the battery level and recharge when necessary. If using an external power source, connect the AC or DC adapter. Regularly check the air intake for blockages and clean filters as needed. For continuous use, ensure the device is set to the correct mode. Always follow the user manual guidelines for safe and effective operation.
3.3. Troubleshooting Common Issues
Common issues with the OxyGo NEXT may include low oxygen flow, device alarms, or battery charging problems. If oxygen flow is low, check the filter for blockages and ensure proper connection. For error alarms, refer to the user manual to identify the cause. If the battery isn’t charging, verify the power source and cable connections. Ensure the air intake is not obstructed. Restart the device if it malfunctions. Consult the troubleshooting section in the manual for detailed solutions. Always follow safety guidelines to resolve issues effectively and maintain optimal performance of the oxygen concentrator.
Accessories and Components
The OxyGo NEXT includes a lightweight backpack for portability, AC and DC power supplies for convenient charging, and additional accessories to enhance user experience and mobility.
4.1. OxyGo NEXT Backpack
The OxyGo NEXT Backpack is designed for utmost portability and comfort. Constructed with durable, lightweight materials, it securely holds the device and features multiple compartments for accessories. Its ergonomic straps and padded back ensure ease of carrying during extended periods. The backpack is ideal for travel, allowing users to maintain their active lifestyle without compromising oxygen therapy. The sleek design blends functionality with style, making it an essential accessory for OxyGo NEXT users seeking convenience and mobility.
4.2. AC and DC Power Supply
The OxyGo NEXT comes with an AC and DC power supply, ensuring uninterrupted oxygen delivery in various settings. The AC power adapter is designed for home use, while the DC power option enables operation in vehicles. This dual functionality allows seamless switching between power sources, providing flexibility for both stationary and mobile use. The power supply is specifically engineered to meet the device’s energy requirements, ensuring reliable performance and safety. This versatility makes the OxyGo NEXT an ideal choice for users who need consistent oxygen therapy across different environments and situations.
4.3. Additional Accessories
Beyond the essential components, the OxyGo NEXT offers several additional accessories to enhance usability and portability. These include a double battery option, which extends runtime to up to 13 hours, and a column change guide for easy maintenance. A Bluetooth user guide is also available, enabling seamless connectivity for remote monitoring and control. Additionally, users can access downloadable resources such as manuals and brochures for troubleshooting and operation. These accessories ensure a comprehensive and convenient experience, catering to diverse patient needs and preferences.
Battery Life and Charging
OxyGo NEXT offers a built-in battery lasting up to 4 hours and a double battery option extending runtime to 13 hours. Recharge via AC or DC power in 4-6 hours.
5.1. Battery Duration and Performance
The OxyGo NEXT’s battery provides up to 4 hours of continuous use on a single charge. With the optional double battery, runtime extends to 13 hours, ensuring extended portability. The device automatically switches between batteries, optimizing performance. Charging is convenient via AC or DC power, with a full recharge taking 4-6 hours. This reliable battery system supports active lifestyles, allowing users to manage their oxygen therapy without interruptions, even during extended travel or outdoor activities.
5.2. Charging Options and Guidelines
The OxyGo NEXT can be charged using either AC or DC power, offering flexibility for home, vehicle, or outdoor use. The standard battery charges fully in 4-6 hours, while the double battery option takes 6-8 hours. Ensure the device is turned off during charging to optimize performance. Use only the provided charger to prevent damage. Avoid overcharging, as it may reduce battery longevity. Store batteries in a cool, dry place when not in use. Always follow the user manual’s guidelines for charging to maintain safety and extend the life of your OxyGo NEXT’s battery system.
Maintenance and Care
Regularly clean and sanitize the OxyGo NEXT to ensure optimal performance. Replace filters and parts as specified in the user manual. Use only approved cleaning supplies to avoid damage. Schedule professional servicing annually to maintain efficiency and longevity of the device.
6.1. Cleaning and Sanitizing the Device
Regular cleaning and sanitizing of the OxyGo NEXT are essential to maintain its performance and longevity. Use a soft, damp cloth with mild soap to wipe down the exterior, avoiding harsh chemicals or abrasive materials. Do not submerge the device in water or expose it to excessive moisture. Sanitize the device by wiping it with a 70% isopropyl alcohol solution, ensuring all surfaces are covered. Allow the device to air dry completely before use. Clean the air inlet regularly to prevent dust buildup and ensure proper airflow. Always refer to the user manual for detailed cleaning instructions to avoid damage.
6.2. Replacing Parts and Filters
Regular replacement of parts and filters is crucial for maintaining the OxyGo NEXT’s performance and ensuring patient safety. The air filter should be replaced every 6 months or as indicated by the user manual. Turn off the device and unplug it before replacing any parts. Use only genuine OxyGo replacement filters and components to avoid damage. Refer to the manual for specific instructions on replacing the columns or sensors, if necessary. Properly dispose of used parts and filters. Always order replacement parts from authorized distributors to guarantee compatibility and quality. Consult the manual for detailed guidelines on replacing parts to maintain optimal functionality and safety.
Certifications and Compliance
OxyGo NEXT adheres to rigorous regulatory standards, including FDA clearance and ISO certifications, ensuring safety and efficacy. It meets international medical device guidelines for portable oxygen concentrators.
7.1. Regulatory Approvals and Standards
The OxyGo NEXT is fully compliant with FDA standards and international medical device regulations. It is designed and tested to meet ISO 13485:2016 for quality management and ISO 10993-1 for biocompatibility. The device holds FDA 510(k) clearance, ensuring its safety and efficacy for oxygen therapy. Additionally, it complies with IEC 60601-1 for electrical safety and IEC 60601-1-11 for portable medical devices. The OxyGo NEXT also meets RoHS and WEEE directives, reflecting its commitment to environmental sustainability. These certifications ensure the device operates within strict global standards, providing reliable and safe oxygen delivery for patients worldwide.
Customer Support and Resources
OxyGo NEXT offers comprehensive customer support, including online resources, user manuals, and guides. Dedicated assistance is available for troubleshooting and product inquiries, ensuring optimal user experience.
8.1. Contact Information and Assistance
OxyGo NEXT customers can access dedicated support through various channels. For assistance, visit the official website to find contact forms, phone numbers, and email addresses. Live chat options are also available for immediate inquiries. Additionally, online resources include downloadable manuals and guides to help users troubleshoot or understand their device better. OxyGo NEXT support teams are available to address technical questions, repair requests, or general inquiries. Customers can also submit online forms for personalized assistance, ensuring prompt resolution of any issues. The support team is committed to providing expert help, making it easy for users to maximize their OxyGo NEXT experience effectively.
8.2. Online Resources and Downloads
OxyGo NEXT offers comprehensive online resources to support users. The official website provides downloadable PDF manuals, including the User Manual, Getting Started Guide, Column Change Guide, and Bluetooth User Guide. Additional resources like product brochures and troubleshooting tips are also available. Customers can access these materials by visiting the OxyGo website and navigating to the downloads section. These resources ensure users can easily find guidance on device operation, maintenance, and troubleshooting. Online resources are regularly updated to reflect the latest product information and improvements, helping users stay informed and maximize their OxyGo NEXT experience effectively.